ClassicAire wood vents are designed to last generations. We make sure our wood floor vents can take the weight of everyday life.


Items:
Wood Floor Registers, Various Sizes, White Oak.

Specifications:
2006 International Mechanics Code, Duct Systems, Chapter 6, Duct Construction and Installation, Sec 603.17.1, Floor Registers.

Load Test:
200 lbs. (90.8 kg Concentrated Load Applied to a 2 Inch (51 mm) Diameter Disc. Applied to the most critical area of the exposed face.


Item Description 200 lbs. Static Load Test Ultimate Load at Failure
2-1/4" x 16" Supply Air, Self Rim Passed 992 lbs.
4" x 14" Supply Air, Self Rim Passed 909 lbs.
6" x 14" Supply Air, Self Rim Passed 727 lbs.
8" x 12" Supply Air, Self Rim Passed 497 lbs.
6" x 10" Solid Block, Self Rim Passed 828 lbs.
6" x 12" Solid Block, Self Rim Passed 798 lbs.
6" x 14" Solid Block, Self Rim Passed 718 lbs.


ClassicAire Wood Vent Manufacturing